GN 2
Technical data
Pre-fabricated distribution/collection chamber for connecting ground source heat probes. White chamber shell made of PE, with inspection-friendly, bright interior surface. Entry dome with welded plastic manhole cover DN 600, load class A 15 according to ISO 15398, test load 200kg, optionally 1,500 kg, watertight with locking mechanism. Telescopic extension possible.
Optional:
Anti-buoyancy protection, branch control valves
Probe circuits:
2- to 24-fold
Connections:
Probes: Ø 25 mm to 50 mm
Heat pump: Ø 40 mm to 63 mm
Maximum allowable operating pressure: 10 bar
Heat pump connection:
- d 63 x 5.73 mm, with PVC ball valve
- d 75 x 6.82 mm, with butterfly valve
- d 110 x 10.0 mm with butterfly valve
- d 125 x 11.4 mm with butterfly valve
- d 140 x 12.73 mm with butterfly valve
- d 160 x 14.55 mm with butterfly valve
Circuit connection:
- d 25 x 2.27 mm
- d 32 x 2.91 mm
- d 40 x 3.64 mm
- d 50 x 4.55 mm
Standard flow meter:
- 2-12 l/min
- 8-28 l/min
- 5-42 l/min
- 35-70 l/min
Alternative:
- with Hydrocontrol including measuring valves in probe return
Material:
Chamber, pipe: PE
Ball valves: PVC
Measuring valves: Plastic
Seals: EPDM
Dimensions:
Length: 1,556 mm
Width: 1,156 mm
Height: 1,150 mm
Empty weight:
70 kg
Installation depth:
Maximum soil cover 0.4 meters above the chamber
Brine distribution chambers must be liquid-tight and preferably made of PE material. Suitable shut-off devices must be provided in the flow and return to each circuit or probe. Appropriate control devices must be installed on the distributors for the hydraulic balancing of the probes. Filling and ventilation fittings must be provided.
Static requirements must be considered during chamber installation and backfilling. Special requirements such as traffic loads or installation in standing water must be taken into account in the structural chamber design and must be inquired about separately. Depending on the load case, additional on-site measures for load distribution or buoyancy control may be required.
The chamber must be backfilled in layers with non-cohesive filling material that complies with the relevant standards and must be compacted in layers. The filling material must be easily compactable, permeable, shear-resistant, frost-proof, and free from sharp objects. The specifications for bedding according to DVGW W 400-2 and ATV-A 127 worksheets as well as DIN EN 805 must be observed. Building over and/or influences from foundation loads of buildings or similar must be excluded. The corresponding distances from buildings or other structures must be maintained.
The manufacturer’s installation instructions must be observed.
Product description
- The GN 2 distribution chamber contains a factory pre-assembled, installed and pressure-tested distributor/collector PE 100-RC, horizontally arranged
- Including 2 pieces of 1″ filling and ventilation fittings
- 2 pieces of connections to the heat pump: Heat pump connectors made of PE 100-RC solid-wall pipe with shut-off valve, radially removable
- Probe flow connection: Probe connector made of PE 100-RC solid-wall pipe with PVC ball valve, radially removable
- Probe return connection: Probe connector made of PE 100-RC solid-wall pipe with lockable and adjustable flow meter, radially removable
- All probe and heat pump connections are welded watertight to the chamber wall and protrude approximately 100 mm on the outside